MAX17030/MAX17036

1/2/3-Phase Quick-PWM
IMVP-6.5 VID Controllers

30

______________________________________________________________________________________

When pulse-skipping, the controller blanks the upper
PWRGD and CLKEN thresholds. Upon entering pulse-
skipping operation, the controller temporarily sets the
OVP threshold to 1.5V, preventing false OVP faults
when the transition to pulse-skipping operation coin-
cides with a VID code change. Once the error amplifier
detects that the output voltage is in regulation, the OVP
threshold tracks the selected VID DAC code. The
MAX17030/MAX17036 automatically use forced-PWM
operation during soft-start and soft shutdown, regard-
less of the DPRSLPVR and PSI configuration.

Automatic Pulse-Skipping Switchover

In skip mode (DPRSLPVR = high), an inherent automatic
switchover to PFM takes place at light loads (Figure 8).
This switchover is affected by a comparator that trun-
cates the low-side switch on-time at the inductor cur-
rent’s zero crossing. The zero-crossing comparator
senses the inductor current across the low-side
MOSFETs. Once V

LX

drops below the zero-crossing

comparator threshold (see the

Electrical Characteristics

),

the comparator forces DL low. This mechanism causes
the threshold between pulse-skipping PFM and non-
skipping PWM operation to coincide with the boundary
between continuous and discontinuous inductor-current
operation. The PFM/PWM crossover occurs when the
load current of each phase is equal to 1/2 the peak-to-
peak ripple current, which is a function of the inductor
value (Figure 8). For a battery input range of 7V to 20V,
this threshold is relatively constant, with only a minor
dependence on the input voltage due to the typically

low duty cycles. The total load-current at the PFM/PWM
crossover threshold (I

LOAD(SKIP)

) is approximately:

Power-Up Sequence (POR, UVLO)

The MAX17030/MAX17036 are enabled when SHDN is
driven high (Figure 9). The reference powers up first.
Once the reference exceeds its undervoltage-lockout
(UVLO) threshold, the internal analog blocks are turned
on and masked by a 150µs one-shot delay. The PWM
controller then begins switching.

I

T

V

L

V

V

V

LOAD SKIP

SW OUT

IN

OUT

IN

(

)

= ⎛

⎝⎜


⎠⎟

×


⎝⎜

-

2

⎠⎠⎟

I

PEAK

I

LOAD

= I

PEAK

/2

INDUCTOR CURRENT

TIME

0

L

V

IN

– V

OUT

∆t

∆I

=

ON-TIME

Figure 8. Pulse-Skipping/Discontinuous Crossover Point

FORCED-PWM

t

BLANK

20

µs TYP

t

BLANK

60

µs TYP

t

BLANK

5ms TYP

t

BLANK

20

µs TYP

VID (D0–D6)

V

CORE

IMVPOK

INTERNAL

PWM CONTROL

V

CC

SOFT-START

1/4 SLEW RATE SET

BY R

TIME

SHDN

IGNORE

VID

IGNORE

VID

PULSE-SKIPPING

CLKEN

SOFT-SHUTDOWN
1/4 SLEW RATE SET
BY R

TIME

Figure 9. Power-Up and Shutdown Sequence Timing Diagram