8

A I R B A G I T. C O M S U S P E N S I O N S

2 6 0 S . H I B B E R T, M E S A , A Z P H . 8 0 0 - 8 4 2 - 8 7 8 9

5. MOUNT THE HEIGHT SENSOR TO THE FRAME SO THAT THE TOP LINKAGE BALL JOINT IS

OVER THE PREVIOUSLY MARKED SPOT ON THE FRAME. THE ARM OF THE HEIGHT SENSOR

SHOULD BE SET IN THE MIDDLE OF ITS TRAVEL. DO NOT CONNECT THE LINKAGE YET.

6. INFLATE THE BAGS ALL THE WAY TO MAXIMUM LIFT.

7. CHECK TO MAKE SURE THE LINKAGE CAN BE CONNECTED BETWEEN THE LINK AND THE

HEIGHT SENSOR WITHOUT

OVERTRAVELING THE HEIGHT SENSOR OR WITHOUT AN EXCESSIVE AMOUNT OF ANGLE

BETWEEN THE HEIGHT SENSOR

ARM AND THE LINKAGE. DO NOT CONNECT THE LINKAGE YET. (SEE BELOW)

8. DEFLATE THE BAGS ALL THE WAY DOWN TO THE LOWEST POINT.

9. CHECK TO MAKE SURE THE LINKAGE CAN BE CONNECTED BETWEEN THE LINK AND THE

HEIGHT SENSOR WITHOUT OVERTRAVELING THE HEIGHT SENSOR AND WITHOUT AN

EXCESSIVE AMOUNT OF ANGLE BETWEEEN THE HEIGHT SENSOR ARM AND THE LINKAGE. TAKE

INTO CONSIDERATION THAT IF A VEHICLE IS LAID OUT ON THE FRAME RAILS AND THE FRONT IS

THEN LIFTED UP THE REAR SUSPENSION WILL TRAVEL HIGHER THAN WHEN IT IS LAID OUT

COMPLETELY AND COULD OVER TRAVEL THE SENSOR.

10. ONCE THE SENSORS HAVE BEEN THOROUGHLY CHECKED THE LINKAGE CAN BE CONNECTED.

11. THE WIRES CAN NOW BE RAN TO THE SMART-RIDE RELAY CONTROL BOX.

TIP: MARK THE BLUE PLUG TO IDENTIFY WHICH CORNER THE HEIGHT SENSOR IS MOUNTED TO.

OVER ROTATED

MOUNTED UPSIDE DOWN

BAD LINKAGE ANGLE

BAD LINKAGE

ANGLE

TOO LITTLE

SENSOR TRAVEL

BAD HEIGHT SENSOR CONFIGURATIONS