After installation of the height sensors a calibration is required so the Smart-Ride can better understand your suspen-

sion. The calibration process converts the vehicles suspension travel into a scale 0.0 - 9.9. The Smart-Ride then

displays the vehicles position based on this scale. The 0.0 - 9.9 Scale is not a reference to ride height inches.

Cycle your suspension up and down to verify that the height sensors are communicating properly with the Smart-

Ride system and that the height values are changing with the suspension.

Setup Screen #3 Calibrate Minimum Height.

1. Lower the vehicle all the way down to its lowest point.

2. Press the center of the Smart-Ride Button once and then the press the

right side of the Smart-Ride button “>” button until you reach Setup

Screen #3.

3. Press and hold the “All” Down button until all of the height displays

read 0.5. Each individual control buttons can also be used to set the

display at 0.5.

4. Press the center of the Smart-Ride Button to exit out of the calibration

mode.

Safety Height Alarm

The software has an alarm that will beep when any of the vehicle’s height

sensors are between 0.0- 1.5 and 8.5 - 9.8. This option is controlled from

Setup Screen #3 by pressing the “D” button.

2 Beeps = Off and 4 Beeps = On

Setup Screen #4 Calibrate Maximum Height.

1. Raise the vehicle all the way up to its highest point.

2. Press the center of the Smart-Ride Button once and then the press the

right side of the Smart-Ride button “>” button until you reach Setup

Screen #4.3. Press and hold the “All” up button until all of the height

displays read 10. Each individual control buttons can also be used to set

the display at 9.8.

4. Press the center of the Smart-Ride Button to exit out of the calibration

mode.

Advertising