After installation of the height sensors a calibration is required so the Smart-Ride can better understand your suspen-

sion. The calibration process converts the vehicles suspension travel into a scale 0.0-10.0. The Smart-Ride then

displays the vehicles position based on this scale. The 0.0-10.0 Scale is not a reference to ride height inches.

Cycle your suspension up and down to verify that the height sensors are communicating properly with the Smart-

Ride system and that the height values are changing with the suspension.

Calibration Min. Height.

1. Lower the vehicle all the way down to its lowest point.

2. Press the center of the Smart-Ride Button once and then the press the right side of the Smart-Ride button “>”

button until you reach Setup Screen #3.

3. Press and hold the “All” Down button until all of the height displays read 0.5. Each individual control buttons can

also be used to set the display at 0.5.

4. Press the center of the Smart-Ride Button to exit out of the calibration mode.

Calibration Max. Height.

1. Raise the vehicle all the way up to its highest point.

2. Press the center of the Smart-Ride Button once and then the press the right side of the Smart-Ride button “>”

button until you reach Setup Screen #4.

3. Press and hold the “All” up button until all of the height displays read 10. Each individual control buttons can also

be used to set the display at 10.0.

4. Press the center of the Smart-Ride Button to exit out of the calibration mode.