Replacement parts – Factory Direct Hardware Hansgrohe 10402001 Axor Starck X User Manual
Page 5

5
•
Remove the handle screw. Pull the
green high temperature limit stop
straight off the cartridge.
•
Reinstall the high temperature limit stop
so that the positioning pin on the
cartridge is in the hole for the desired
high temperature. The temperatures
shown on the diagram assume an
incoming cold water temperature of
50
o
F and an incoming hot water
temperature of 140
o
F.
•
Test the unit. Reposition the high
temperature limit stop again if required.
•
Reinstall the nut cover. Reinstall the
handle screw and tighten four complete
turns. Reinstall the handle and continue
tightening the screw. Reinstall the screw
cover.
1
Handle
10490XXX
1.1
Screw cover
96338000
2
Flange
96395000
3
Nut
96461000
4
Cartridge
92730000
5
Flange
96467000
6
S-connector
7
Diverter
94077000
8
Diverter knob
96466XXX
9
Check valve
94074000
10
noise reducer
96429000
11
hose
28282XXX
12
screen washer
13
handshower
28531XXX
14
spray former
97467000
XXX = color
000 = chrome
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1.1
Replacement Parts