35

EASY DMX SO

XII 2009

Installation

Expanding the system

Master-slave circuit

In a master-slave circuit, EASY DMX, OT EASY 60 II or DALI EASY III control units

can be connected together. The devices use a master-slave communication concept

to synchronize with each other.

CAUTION!
Master-slave connection lines conduct protective extra-low voltage signals!

•

Do not route together with power supply or lamp lines.

•

Ensure that the master-slave connection lines are sufficiently insulated against the

power supply or lamp lines.

System limitations

In order to set up a master-slave circuit, the following rules have to be observed:

•

Extension of more than one EASY DMX is allowed; the limit of 64 independent light

points must not be exceeded.

•

Max. number of DALI EASY III and OT EASY 60 II and related limitations must be

observed. See separate instruction sheets of DALI EASY III and OT EASY 60 II.

•

Max. total EASY line length (without EASY system coupler): 100 m

•

Max. 50 m to pushbutton coupler.

•

Every EASY system requires exactly one master control unit in the complete sys-

tem. Configure all other control units as slaves.

•

Max. number of independent light points (see examples in the following table):
• EASY system: 64
• EASY DMX 64x4 SO: 64
• EASY DMX 32x4 SO: 32
• EASY DMX 16x4 SO: 16
• OT EASY 60 II: 1
• DALI EASY III: 1

Examples

Total no. of

light points

EASY DMX

32x4

EASY DMX

16x4

DALI EASY III

OT EASY

60 II

34

1 x

1 x

1 x

32

2 x

17

1 x

1 x