De en fr it es, Easy dmx – OSRAM EASY DMX 16x4 SO User Manual
Page 39
Advertising

DE
EN
FR
IT
ES
39
EASY DMX SO
XII 2009
Operation
“Multiple light points” applications
RGB fixtures of light point 1 use the DMX channels 1, 2 and 3,
RGB fixtures of light point 2 use the DMX channels 4, 5 and 6,
and so on.
7,8,9
1,2,3
1,2,3
1,2,3
4,5,6
EASY DMX
10,11,12
10,11,12
O
n
1
2
O
n
1
2
L
N
EASY signal
t a (°C )
0...+ 50
2
1
3
4
DMX out
+
-
Shield
Sync
Cmd
1 - ON 120Ω Termin.
1 - ON Test Mode
2 - ON Slave / OFF Master
Temp.-Test
t
C
= 60°C
110
Made in Italy by OSRAM
A6022790072
2 - N.C.
wire preparation
push in
s+f: 0.5 – 2.5
10 - 12 mm
EASY DMX 16x4 SO
2
110-240 V
_
~
60-40mA
0/50/60Hz
EASY
signal
DMX addresses
DMX cable
First light point
Second light point
Fourth light point
DMX addresses
DMX addresses
DMX addresses
DMX addresses
Third light point
DMX addresses
DMX addresses
Advertising