Setting the fade and cycle time, Example of a sequence – OSRAM OPTOTRONIC OT EASY 60 II User Manual
Page 15
15
OT EASY 60
IV 2009
Operation
Setting the fade and cycle time
Set the fade time for the sequencer mode and the cycle time for the daylight simula-
tion.
To increase the time: „Start/Time+“ button
To decrease the time: „Stop/Time
−“ button
Proceed as follows:
Step
Task
1
Press the button for at least 3 seconds. The time is shown on the display;
see below.
2
Single steps: Short press
Fast forward: Long press
Operating mode
Display
Interval
Sequencer mode (fade time)
Effect Lighting
Wellness
Long Time
Tenths of a second
Seconds
Minutes
Daylight simulation (cycle time)
Hours
Example of a sequence
Fade time
Hold time*
Brightness
Time
Red:
Green:
Blue:
Scene 1
Scene 2
Scene 3
*The hold time is automatically set to 25% of the set fade time.
Scene 1:
Ch1 (red) = max.; Ch2,Ch3,Ch4 = min.
Scene 2:
Ch2 (green) = max; Ch1,Ch3,Ch4 = min.
Scene 3:
Ch3 (blue) = max.; Ch1,Ch2,Ch4 = min.
Scene 4:
Ch1...Ch4 = off (is skipped)