4 controlling the scanner from the pos system, 5 standard available interface cables – SCANTECH ID (Champtek company) SIRIUS S-7030 User Manual

Page 21

Advertising
background image

Installation

15

2.4 CONTROLLING THE SCANNER FROM THE POS SYSTEM


The Sirius S-7030 can be controlled from the POS system via the RS-232
interface or USB/COM Port Emulation. Control is achieved by transmitting the
following single byte commands to the scanner. In the Scantech default setting
the following commands are available (more details available upon request):

ASCII code

05

Hex

OE

Hex

OF

Hex

12

Hex

14

Hex

Function

Power-up re-initialization

Enable (cancels disable)

Disables the scanner

Puts scanner into Sleep

Wake (cancels sleep)

Byte is also called:

ENQ or <Ctrl-E>

Shift Out or <Ctrl-N>

Shift In or <Ctrl-O>

DC2 or <Ctrl-R>

DC4 or <Ctrl-T>


When the scanner is disabled, the motor of the scanner will stay on,
until the scanner goes into sleep mode.


2.5

STANDARD AVAILABLE INTERFACE CABLES


On the next pages you see the standard available interface cables with some
additional information.

Note that the power injector may be used to insert the DC power from the

optional external power supply. However if your POS/PC system provides
sufficient power directly via the data port, no external power supply is required.

A safety measure prevents from damage in case you connect a power supply

where it is not required (by disconnecting the power from the POS/PC system).

If you are using the Sirius with USB interface, no external power supply is

required at all.