The data plate, Optional sensors – Xylem GK GV (8201, 8201X) User Manual

Page 15

Advertising
background image

• The sensors must be connected to either the SMR 311 monitoring equipment or an

equivalent equipment.

• The monitoring equipment must be of a design that makes automatic restart

impossible.

• Information in the junction box shows if the pump is equipped with optional sensors

Optional sensors

LD LD is a miniature float switch for detection of liquid in the stator housing. Due to its

design it is best suited for pumps in a vertical position. The LD sensor is installed in the
bottom of the stator housing.

The data plate

The data plate

The data plate is a metal label located on the main body of the pump. The data plate lists
key product specifications.
Ex- and MSHA-approved products also have approval plates. They are described below, if
applicable.

2

13

12

14

22

21
20

17 18

19

16

15

9

10

11

8

7

6

5

4

3

1

WS000351A

1.

Curve code/Propeller code

2.

Serial number

3.

Product number

4.

Country of origin

5.

Additional information

6.

Phase; type of current; frequency

7.

Rated voltage

8.

Thermal protection

9.

Thermal class

10. Rated shaft power

11. International standard

12. Degree of protection

13. Rated current

14. Rated speed

15. Maximum submergence

16. Direction of rotation: L=left, R=right

17. Duty class

18. Duty factor

19. Product weight

20. Locked rotor code letter

21. Power factor

22. Maximum ambient temperature

The name plate

The name plate is a metal label located on the main body of the pump. This plate lists key
product specifications for the branded pump.

Product Description

GK, GV (8201, 8201X) Installation, Operation, and Maintenance Manual

13

Advertising