Cable charts – Xylem GK GV (8201, 8201X) User Manual

Page 21

Advertising
background image

The single phase pumps must be equipped with a starter which has start and run
capacitors.
1. If thermal contacts are included in the pump installation, connect the T1 and T2 control

conductors to the monitoring equipment.

NOTICE:
Ex-approved products must always have the thermal contacts connected irrespective
of the ambient temperature.

2. Connect the mains leads (L1, L2, L3, and earth [ground]) to the starter equipment.

For information about the phase sequence and the color codes of the leads, see

Cable

charts

(page 19).

3. Check the functionality of the monitoring equipment:

a) Check that the signals and the tripping function work properly.
b) Check that the relays, lamps, fuses, and connections are intact.
Replace any defective equipment.

Cable charts

Description

This topic contains general connection information. It also provides cable charts that show
connection alternatives for use with different cables and power supply.

L2

L1

L2

L3

L3

L1

WS000509B

WS000509C

L2

L3

L1

L1

L3

L2

T1 T2

Figure 3: Phase sequence

Connection locations

The figures in this section illustrate how to interpret the connection strip symbols.

Installation

GK, GV (8201, 8201X) Installation, Operation, and Maintenance Manual

19