Inspection – Xylem GK GV (8201, 8201X) User Manual

Page 35

Advertising
background image

Type of service

Purpose

Inspection interval

to secure performance and pump

efficiency are defined and decided

for each individual application. It

can include such things as impeller

trimming, wear part control and

replacement, control of zinc-anodes

and control of the stator.

conditions at media (liquid)

temperatures <40°C.

Major overhaul

To secure a long operating lifetime

for the product. It includes

replacement of key components

and the measures taken during an

inspection.

Up to every 3 years. This interval

apply to normal applications and

operating conditions at media

(liquid) temperatures <40°C.

NOTICE:
Shorter intervals may be required when the operating conditions are extreme, for example
with very abrasive or corrosive applications or when the liquid temperatures exceed 40°C
(104°F).

Inspection

Service item

Action

Cable

1. If the outer jacket is damaged, replace the cable.
2. Check that the cables do not have any sharp bends and are not

pinched.

Connection to power

Check that the connections are properly tightened.

Electrical cabinets

Check that they are clean and dry.

Impeller

1. Check the impeller clearance.
2. Adjust the impeller, if necessary.

Stator housing

1. Drain all liquid, if any.
2. Check the resistance of the leakage sensor.

Normal value approximately 1530 ohms, alarm approximately

330 ohms.

Insulation

Use a megger maximum 1000 V.

1. Check that the resistance between the earth (ground) and

phase lead is more than 5 megohms.

2. Conduct a phase-to-phase resistance check.

Junction box

Check that it is clean and dry.

Lifting device

Check that local safety regulations are followed.

Lifting handle

1. Check the screws.
2. Check the condition of the lifting handle.
3. Replace if necessary.

O-rings

1. Replace the oil plug O-rings.
2. Replace the O-rings at the entrance or junction cover.
3. Grease the new O-rings.

Maintenance

GK, GV (8201, 8201X) Installation, Operation, and Maintenance Manual

33

Advertising