Service item

Action

Personnel safety devices

Check the guard rails, covers, and other protections.

Rotation direction

Check the impeller rotation.

Oil housing

Fill with new oil, if necessary.

Terminal block/closed end splice

Check that the connections are properly tightened/connected.

Thermal contacts

Normally closed circuit; interval 0–1 ohm.

Voltage and amperage

Check the running values.

Major overhaul

For a major overhaul, take this action in addition to the tasks listed under Inspection.

Service item

Action

Support and main bearing

Replace the bearings with new bearings.

Mechanical seal

Replace with new seal units.

Service in case of alarm

For information about indication values for sensors, see

Sensor connection characteristics

(page 26).

Replace the impeller

WS006089A

Figure 9: C-impeller

WS006090A

Figure 10: D-impeller

Required tools:

• 6 mm hexagon bit adapter with an extension of at least 125 mm (4.92 in.)
• Impeller puller

If applicable, contact your local sales and service representative for correct type and
size.

• Rod (wooden or copper) for locking the impeller in place, if applicable.
• Two crowbars, if applicable