Service the pump, Fill with oil – Xylem GK GV (8201, 8201X) User Manual
Page 34
WS001760A
2. Place a container under the pump and turn the pump.
Fill with oil
The oil should be a medical white oil of paraffin type that fulfills FDA 172.878 (a) and
viscosity close to VG32.
1. Replace the O-ring of the oil plug.
2. Fill with oil.
Quantity: approximately 0.6 L (0.63 qt.)
WS001762A
3. Refit the oil plug and tighten.
Tightening torque: 10-40 Nm (7.5-29.5 ft-lbs)
Service the pump
Type of service
Purpose
Inspection interval
Initial inspection
To make a check up of the pump
condition by a Xylem authorized
service representative and, based
on the result and findings from
these measures, to determine the
intervals for periodical inspection
and major overhaul for the specific
installation.
Within the first year of operation.
Periodical inspection
To prevent operational interruptions
and machine breakdown. Measures
Up to every year. Applies to normal
applications and operating
Maintenance
32