Service the pump, Fill with oil – Xylem GK GV (8201, 8201X) User Manual

Page 34

Advertising
background image

WS001760A

2. Place a container under the pump and turn the pump.

Fill with oil

The oil should be a medical white oil of paraffin type that fulfills FDA 172.878 (a) and
viscosity close to VG32.
1. Replace the O-ring of the oil plug.
2. Fill with oil.

Quantity: approximately 0.6 L (0.63 qt.)

WS001762A

3. Refit the oil plug and tighten.

Tightening torque: 10-40 Nm (7.5-29.5 ft-lbs)

Service the pump

Type of service

Purpose

Inspection interval

Initial inspection

To make a check up of the pump

condition by a Xylem authorized

service representative and, based

on the result and findings from

these measures, to determine the

intervals for periodical inspection

and major overhaul for the specific

installation.

Within the first year of operation.

Periodical inspection

To prevent operational interruptions

and machine breakdown. Measures

Up to every year. Applies to normal

applications and operating

Maintenance

32

GK, GV (8201, 8201X) Installation, Operation, and Maintenance Manual

Advertising