Make the electrical connections, General precautions – Xylem GK GV (8201, 8201X) User Manual

Page 18

Advertising
background image

The stand is integrated with the pump housing and the hose is connected to pump using
thread coupling.
These requirements and instructions only apply when the installation is made according to
the dimensional drawing. For information about the different installation types, see Parts
List.

WS000114A

Figure 2: Installation with stand

1. Run the cable so that it has no sharp bends, is not pinched, and cannot be sucked into

the pump inlet.

2. Connect the discharge line.
3. Lower the pump into the sump.
4. Place the pump on the base and make sure it cannot fall over or sink.

Alternatively, the pump can be suspended with a lifting chain just above the sump
bottom. Make sure that the pump cannot rotate at startup or during operation.

5. Connect the motor cable and the starter and monitoring equipment according to the

separate instructions.
Make sure that the impeller rotation is correct. For more information, see

Check the

impeller rotation

(page 27).

Make the electrical connections

General precautions

Electrical Hazard:
• A certified electrician must supervise all electrical work. Comply with all local codes and

regulations.

• Before starting work on the unit, make sure that the unit and the control panel are

isolated from the power supply and cannot be energized. This applies to the control
circuit as well.

• Leakage into the electrical parts can cause damaged equipment or a blown fuse. Keep

the end of the motor cable above the liquid level.

• Make sure that all unused conductors are insulated.
• There is a risk of electrical shock or explosion if the electrical connections are not

correctly carried out or if there is fault or damage on the product.

Installation

16

GK, GV (8201, 8201X) Installation, Operation, and Maintenance Manual