Monitoring equipment, The data plate, Optional sensors – Xylem GK GV (8204, 8204X) User Manual

Page 15

Advertising
background image

Position

Part

Description

3

Mechanical seals

Type: Mechanical face seal

4

Seal housing

Includes a coolant that lubricates and cools the seals; the housing acts as a buffer between the
pumped fluid and the electric motor.

5

Main bearing

The bearing consisting of a two-row angular contact ball bearing.

6

Motor

For information about the motor, see .

Motor data

(page 49).

7

Stator housing

The pump is cooled by the ambient liquid/air.

8

Support bearing

The bearing consisting of a two-row ball bearing.

9

Inspection

chamber

Equipped with an FLS 10 leakage sensor to prevent damages to the motor.

10

FLS 10

For information about FLS 10, see

Monitoring Equipment

(page 13).

Monitoring Equipment

The following applies to the monitoring equipment of the pump:

• The stator incorporates thermal contacts connected in series that activates the alarm at

overtemperature.

• The thermal contacts open at 140°C (285°F).
• Ex-approved pumps must have thermal contacts connected to the control panel.
• The sensors must be connected to either the SMR 311 monitoring equipment or an

equivalent equipment.

• The monitoring equipment must be of a design that makes automatic restart

impossible.

• Information in the junction box shows if the pump is equipped with optional sensors

Optional sensors

LD LD is a miniature float switch for detection of liquid in the stator housing. Due to its

design it is best suited for pumps in a vertical position. The LD sensor is installed in the
bottom of the stator housing.

The data plate

The data plate

The data plate is a metal label located on the main body of the pump. The data plate lists
key product specifications.

Product Description

GK, GV (8204, 8204X) Installation, Operation, and Maintenance Manual

13