Change the coolant: Ex-version
2
1
2
WS000090A
1.
Inspection plug
2.
Coolant plugs
Empty the coolant
WARNING:
The seal housing may be pressurized. Hold a rag over the inspection/ filling plugs to
prevent splatter.
1. Empty the coolant in the inspection chamber:
a) Remove the inspection plug.
WS001505A
b) Pump out any coolant from the inspection chamber, as shown here.
Maintenance