NOTICE:

• Thermal contacts are incorporated in the pump.
• Thermal contacts must never be exposed to voltages higher than 250 V, breaking

current maximum 4 A. It is recommended that they are connected to 24 V over
separate fuses to protect other automatic equipment.

1. If thermal contacts are included in the pump installation, connect the T1 and T2 control

conductors to the monitoring equipment.

NOTICE:
Ex-approved products must always have the thermal contacts connected irrespective
of the ambient temperature.

2. Connect the mains leads (L1, L2, L3, and earth [ground]) to the starter equipment.

For information about the phase sequence and the color codes of the leads, see

Cable

charts

(page 22).

3. Check the functionality of the monitoring equipment:

a) Check that the signals and the tripping function work properly.
b) Check that the relays, lamps, fuses, and connections are intact.
Replace any defective equipment.