8figure 5 – Xylem IM129 R01 BF03S User Manual

Page 8

Advertising
background image

8

Figure 5

NORMAL FLOAT POSITION

WITH CORRECT AIR CUSHION

FLOAT CONTROL VALVE CLOSED.

CALIBRATED ORIFICE

AIR VALVE (2)

NORMAL WATER LEVEL

FLOAT CONTROLLED VALVE OPEN

3

16

" O.D.

COPPER TUBING

AIR VALVE

IN PUMP CASING

VALVE STEM DEPRESSED BY

FLOAT ROD EXTENSION (1)

FLOAT IN RAISED POSITION

WATER

WATER LEVEL ABOVE

NORMAL CHAMBER NEEDS AIR.

AIR

AIR PASSES DOWN COPPER TUBE

INTO WATER PUMP THROUGH THE

AIR VALVE AND THEN INTO TANK

WITH THE WATER

VALVE ASSEMBLY

ON AIR VOLUME

CONTROL

1

16

"

SUCTION EFFECT OF WATER PUMP

WHEN RUNNING DRAWS AIR

THROUGH OPEN VALVE HERE.

VALVE IS OPENED

BY DEPRESSING

THIS STEM.

VALVE SEAT

VALVE IS SHOWN IN

CLOSED POSITION.

CALIBRATED ORIFICE

PROCEDURE FOR REPLACING AIR VOLUME

CONTROL TUBE IF DAMAGED

Slip compression nut and sleeve over end of tube and

insert end of tube all the way in counter bore of fitting.

Then pull tube back about

1

16

" so there is a space

between end of tube and bottom of counter bore. With

tube in this position, tighten compression nut securely.

CAUTION: Be sure tube is in line with counter bore and

nut is not cross threaded.