3.1.9

Motor powered by a frequency converter

Only specially ordered motors can be powered with a frequency converter.

For further information, please contact our Sales and Service Department.

If the motor is combined with a frequency converter, downgrade power by 10% and make sure you never exceed the

rated input frequency of the motor.

To ensure the motor is properly cooled, the minimum water flowrate at the minimum frequency of use must equal the

minimum flowrate indicated in the previous points.

For further information, please contact our Sales and Service Department.

3.1.10

Motor powered by a generating set

For information, please contact our Sales and Service Department.

3.1.11

Special applications

For situations other than those described for the nature of the liquid and/or installation, please contact our Sales and

Service Department.

3.1.12

Improper Use

Improper use of the motor may create dangerous conditions and cause personal injury and/or damage to property.

Improper use includes:

-

working with liquids other than water

-

working at water temperatures higher than 35 °C without downgrading the motor

-

working with a cooling water flowrate of less than 0.3 m/s

-

exceeding the maximum number of starts per hour

3.2

Technical specifications

For performance data, please refer to the rating plate attached to the motor.

For any requirements, please contact our Sales and Service Department.

3.3

Warranty

Please refer to the sales contract for further information.

4.

Transport and storage

Information for carriers and installers

The motors are supplied in various shapes and sizes of cardboard boxes.

Store packed products at an ambient temperature ranging from –5° to +40°C.

Packed products must be transported, handled and stored horizontally.

Protect products from humidity, heat and physical damage (knocks, falls, …).

Do not place heavy objects on boxes.

Lift and handle products carefully, using suitable lifting equipment. Observe accident prevention regulations.

Do not lift or carry motors by their power cord.

On receipt of the motor, check the box for signs of damage. If the product is damaged, inform our dealer within 8 days of delivery.

If you cannot reuse the box, dispose of it according to local bylaws governing sorted waste disposal.

Harness the product safely before lifting and handling it.
For further information ⇐ section 3.1.

5.

Installation

Information for installers

Before installing the motor, read this instructions manual and the one supplied with the pump or electric pump to

which the motor will be coupled. Keep both manuals with care.

If the product shows clear signs of damage, do not proceed with installation, but contact the Technical Service Centre.

This product may only be installed by qualified and experienced personnel.

Use suitable equipment and protective devices. Observe all accident prevention regulations.

Carefully read the working limits specified in section

3.1.

Always refer to current local and/or national regulations, legislation and bylaws governing installation and water and power connections.

5.1

Selecting the electrical panel

Motors must be suitably protected against overloads and short circuits.

The following starting systems can be used: impedance, autotransformer, soft-start.

Make sure the panel power ratings match those of the pump. Incompatible combinations may cause faults and fail to

fully protect the motor.

Check the working limits specified in section 3.1.

Before installing, carefully read the instructions supplied with the electrical panel.

For further information, please contact our Sales and Service Departmen

WARNING

WARNING

WARNING

WARNING

WARNING

Advertising