3.11.2 Usage of the auxiliary voltage

The DIQ/S 182 XT-4-PR has a 24 V output (designation,
HILFSSPANNUNG or AUXILIARY VOLTAGE on the terminal strip).
You can use this auxiliary voltage for the relay-controlled opening of the
valve in a DIQ/CHV valve module for the compressed air-driven sensor
cleaning function. To do so, you have to connect the auxiliary voltage
output, a free relay contact and the valve connection in the DIQ/CHV in
series. Bridge a terminal of the auxiliary voltage output with a terminal
of a relay output and run a control line from the remaining terminals to
the valve module.

Caution

The auxiliary voltage must not be used for other purposes.

Connection scheme for one sensor with compressed air cleaning

Caution

Run the bridge below the divider so the bridge does not bump
against the circuit board in the lid when the enclosure is closed.

17

Close the enclosure of the DIQ/S 182 XT-4-PR.

X13

X15

X6

X12

X14

X5

X11

X4

X10

X3

X9

X2

X8

X1

Terminal strip
DIQ/S 182

Terminal strip
DIQ/CHV

R1

AUXILIARY

VOLTAGE

VALVE

DISTRUBUTION

R2

R3

Valve
control line

Advertising