1 terminal connections, Terminal connections – YSI IQ SensorNet MIQ/A-PR Module User Manual

Page 11

Advertising
background image

MIQ/(A-)PR

Interface for the PROFIBUS

11

ba76020e01

01/2012

3.2.1

Terminal connections

Fig. 3-3

Terminal connections

To check the wiring, the connection designations of a 9-pole D-SUB
plug connection are given here:

* Wire colors when using a standard PROFIBUS cable.

Pin

Name

Function

1

+5 V BUS

Insulated +5 V from RS 485

2

GND BUS

Insulated GND from RS 485

3

A line

Negative RxD/TxD according to RS 485
specification

4

B line

Positive RxD/TxD according to RS 485
specification

5

Shield

BUS cable screen, connected with PE

6

RTS

Request To Send

Pin

Color*

Name

Function

1

-

2

-

3

Red

B line

Positive RxD/TxD
according to RS 485 specification

4

RTS

Request To Send

5

GND BUS

Reference potential for data wires and
terminating resistors

6

+5 V BUS

Supply voltage for terminating resistors

7

-

8

Green

A line

Negative RxD/TxD
according to RS 485 specification

9

-

1

6

2 3

4

5

Advertising