3 changing the assignment of sensor numbers, Changing the assignment of sensor numbers – YSI IQ SensorNet MIQ/A-PR Module User Manual

Page 22

Advertising
background image

Interface for the PROFIBUS

MIQ/(A-)PR

22

ba76020e01

01/2012

3.6.2

Creating the identical assignment of sensor numbers in
several systems

You want to install several identical IQ S

ENSOR

N

ET

systems and, at

the same time, create the same sequence of sensor number
assignments to the sensors in all systems.

3.6.3

Changing the assignment of sensor numbers

You want to change the assignment of sensor numbers to the sensors
in an already running IQ S

ENSOR

N

ET

system.

Note
When the inactive datasets are deleted, all settings for the sensors are
deleted as well.

1

Carry out a system start without any sensors (see System
operating manual, chapter Installation).

2

Connect the sensors to the system in the required order. For
each sensor, wait until the sensor is recognized by the system
(see System operating manual, chapter Installation).

3

Repeat steps 1 and 2 for all other systems and, while doing so,
keep to exactly the same order when connecting the sensors.

1

Unplug all sensors from the IQ S

ENSOR

N

ET

.

2

Delete all inactive datasets in the list of sensors (see System
operating manual, chapter Deleting inactive datasets of
sensors
).

3

Connect the sensors to the system in the required order. For
each sensor, wait until the sensor is recognized by the system
(see System operating manual, chapter Installation).

Advertising