7.2 OPERATING MODE 1 - Output adjusted manually

In this mode, the pump’s motor speed is adjusted manually using the
front panel touch pad. The motor speed can be adjusted from 0-100%.

tm

CHEM-PRO

C3V | Diaphragm Metering Pump

Made in the USA

MODE

PRIME

Program

Minimum

Maximum

Blue-White Ind.

IP66

NEMA 4X

4

Set the pump for mode 1.
Press the MODE button until MODE 1
is shown on the LCD display.

The %SPEED icon will light.

The large LCD will indicate the
currently programmed percentage of
speed.

4 Enter the programming mode.

Press and MODE button for more than
two seconds.

A blinking ARROW will point to the
word PROGRAM indicating the
program mode has been activated.

MODE

MODE

Press the DOWN button to select the digit to program. The digit will blink
when selected.

Press the UP button to change the selected digit.

Repeat until all digits are programmed.

To exit the programming mode, press the MODE button for more than two
seconds.

The arrow next to the word PROGRAM will disappear.

[

NOTE: If while in the program mode no buttons are pressed within 20
seconds, the circuitry will automatically return to the run

mode, without

saving changes.

MODE

Mode 1

7.3

OPERATING MODE 2 - 4-20 mA input Mode

In this mode, the pump’s motor speed is adjusted automatically based on the
value of the 4-20 mA input signal. Any motor speed can be assigned to either
the minimum or maximum milliamp input values.

tm

CHEM-PRO

C3V | Diaphragm Metering Pump

Made in the USA

MODE

PRIME

Program

Minimum

Maximum

Blue-White Ind.

IP66

NEMA 4X

C3V

Series Operation

PRIME
Button

Green LED
Indicates
pump is
pumping

7.1 How To Operate The C3V

Series

MODE Selection Button

Start/Stop,
To start and stop
the pump

DOWN button,
To Select Digit
To Program

UP button,
To Change
Selected Digit

MODE button is used to
select the mode you would
like to run the pump in. See
below for more MODE
information.

PRIME button is used to
prime the pump. The pump
will run at full speed for 60
seconds.
To stop the priming
function before the 60
seconds, press the
Start/Stop button.

UP button is used to
change the selected digit.

Start/Stop button is used to
Start and Stop the pump.

DOWN button is used to
select the digit to program.

MODE

PRIME

C3V Modes

MODE 0 =

DFD (Diaphragm Failure Detection) On/Off
FVS (Flow Verification System) 0 = OFF, 1-255 Seconds = ON
Please Note: You will not see the FVS icon or be able to configure
the FVS unless an FVS sensor is wired to the C3 pump.

MODE 1 =

Manual Adjustment, 1 - 100% (external input disabled)

MODE 2 =

4-20 mA input

MODE 3 =

0-10 VDC input

MODE 4 =

Frequency input (Hz), also known as pulse input
Frequency (Hz) mode is commonly used in proportional feed
systems. Pump can be wired to a paddlewheel flowmeter,
ultrasonic flowmeter, or any type of high frequency flowmeter.
Pump will smoothly speed up and slow down based on frequency
signals. Range = 1 - 1000 Hz

MODE 5 =

Batch
Batch mode can be used with water meters, contact closure switch,
and other single pulse or low pulse equipment.

In Batch mode, the pumps’ ‘motor speed’ and ‘on time’ is
configured to be initiated by a single pulse or multiple pulses (up to
1,000 pulses). In MODE 5 the pump ‘motor speed’ is fixed
(1 - 100%) for a specified amount of ‘on time’ (0.1 - 199.9 seconds
or 0.1 - 199.9 minutes).