Switcher error responses, Using the command and response tables – Extron Electronics FOX Matrix 14400 User Guide User Manual

Page 29

Advertising
background image

]Login Administrator]
]Login User]
The switcher initiates the login message when a correct administrator or user password has
been entered. If the user and administrator passwords are the same, the switcher defaults
to administrator privileges.

Switcher Error Responses

When the switcher receives a valid SIS command, it executes the command and sends
a response to the host device. If the unit is unable to execute the command because the
command is invalid or it contains invalid parameters, the unit returns an error response to
the host. The error response codes are:
E01 — Invalid input channel number (too large)
E10 — Invalid command
E11 — Invalid preset number
E12 — Invalid output number (too large)
E13 — Invalid value (out of range)
E14 — Illegal command for this configuration
E17 — Timeout (caused only by direct write of global presets)
E21 — Invalid room number
E24 — Privilege violation (Ethernet only. Personnel logged in as users attempting

operations requiring supervisors privileges. Users have access to all view and read

commands [other than the administrator password], and can create ties and

presets, and mute and unmute the output.)

Using the Command and Response Tables

The command and response table begins on

page 25

. Either uppercase or lower case

letters are acceptable in the command field. Symbols, defined starting below and used
throughout the table, represent variables in the command and response fields. Command
and response examples are shown throughout the table. The ASCII to Hex conversion table
below is for use with the command and response table.