Extron FPC 5500 • FPC Installation and Operation

9

f

Ethernet connector (RJ-45) — Connect one end of a Category (CAT) 5e or higher

cable, terminated with RJ-45 connectors, to the FPC 5500 via this RJ-45 Ethernet
connector.

NOTE: The FPC 5500 ships with a 10-foot crossover CAT 5e cable.

For direct connection to the Ethernet port — Plug the RJ-45 connector on the
opposite end of the CAT 5e or higher cable directly into Ethernet port (BME 0 on a
Matrix 12800 system) (see figure

8). Wire the CAT 5e or higher cable as a crossover

cable (see ”

Cabling and RJ-45 connector wiring

” on page 10).

FPC 5500

Matrix 12800

Crossover Cable

MATRIX 12800

WIDEBAND VIDEO

RESET

MATRIX SWITCHER CONTROLLER

FPC 5500

Figure 8.

Connecting the FPC Directly to a Matrix Switcher

For Ethernet connection to the matrix system — Plug the RJ-45 connector on the
opposite end of the CAT 5e or higher cable into the Ethernet LAN on which the matrix
system (BME 0 on a Matrix 12800 system) resides (see figure

9). Wire the CAT 5e or

higher cable as a patch (straight) cable (see ”

Cabling and RJ-45 connector wiring

”

on page 10).

FPC 5500

Matrix 12800

Laptop

Patch Cable

Patch Cable

MATRIX 12800

WIDEBAND VIDEO

RESET

MATRIX SWITCHER CONTROLLER

FPC 5500

Ethernet

Figure 9.

Connecting the FPC through a LAN

g

Audio (Line-Out) — This connector is not used with the FPC 5500.