User presets, Factory patterns – Extron Electronics MVP 104GX User Guide User Manual

Page 23

Advertising
background image

MVP 104GX Operation

3-5

User presets

Before storing any presets, first optimize the window images by setting the
picture controls (contrast, brightness, tint, color), the sizing and positioning
(horizontal and vertical), and the blanking (top, bottom, left, right). See the
“Optimizing the Image” section.

The eight user Preset buttons save/recall eight preset user-defined window
output configurations, including window positioning, sizing, blanking,
priority, test, and audio input selection.

To save the current window configuration, while in the Default Cycle
menu (see Default cycle menu section), press the Store button for three
seconds. The green LED above the store button lights and the amber

LED above or below each Preset
button flashes for 16 seconds. The
message “Select Location To Save”
also appears on the LCD panel
during those 16 seconds. During
this time, press a Preset button to
save the configuration. The amber
LED above or below the selected
user preset button lights and the

message “User Preset Saved” appears on the
LCD panel for 16 seconds. Wait until the
Default Cycle menu resumes before pressing any
other button.

To recall a user preset, while in the Default Cycle
menu, select a user preset button. The preset’s LED lights
amber. Any configuration modification made to a selected

user preset turns the LED off.

Above and below the Preset buttons are slots to attach labels which

identifies the preset configurations. The 8 user presets can also be

saved/recalled through RS-232/RS-422 commands. In addition to

these 8 user presets, 16 more user presets

can be saved/recalled

through RS-232/RS-422 commands only. See the Programmer’s
Guide
chapter.

Factory patterns

While the LCD panel is in the Default Cycle menu (see Default
cycle menu
section), pressing the Factory Patterns button displays
the LCD message “Preset ## of 20 Menu= No Next=Yes”
where ## refers to the factory pattern preset from 01 to 20.
Rotating the Vertical sizing knob recalls the 20 factory
pattern preset window output configurations.
Pressing the Menu button rejects the configuration
(=No), and pressing the Next button accepts the
configuration (=Yes). Any factory pattern preset can
be conveniently stored as a user preset (see the
previous User presets section).

See figure 3-4 for an illustration of the 20 factory pattern presets.

FACTORY

PATTERNS

Preset ## of 20

Menu=No Next= Yes

Select Location
To Save

User Preset
Recalled

User Preset
Saved

PRESETS