Programmer’s guide, Host-to-mvp 104gx communications – Extron Electronics MVP 104GX User Guide User Manual

Page 40

Advertising
background image

Programmer’s Guide

MVP 104GX Programmer’s Guide

5-2

Remote Control Port (RS-232/RS-422)

The MVP 104GX RS-232/RS-422 port connector is used to connect to a host
or external controlling device, such as a computer or control system which
can generate the proper command codes and recognize the MVP 104GX
responses.

The MVP 104GX comes from the factory configured for RS-232. To set the
MVP 104GX for RS-422 operation, see “Configuring the MVP 104GX for
RS-422” in the appendix.

The RS-232/RS-422 connector is a 9-pin D female (see illustration above)
with the following pin designations:

Pin

RS-232

Description

RS-422

Description

1

not used

Tx(-)

Transmit data (-)

2

Tx

Transmit data

Tx(+)

Transmit data (+)

3

Rx

Receive data

Rx(+)

Receive data (+)

4

not used

Rx(-)

Receive data (-)

5

Gnd

Signal ground

Gnd

Ground

6

not used

not used

7

not used

not used

8

not used

not used

9

not used

not used

The protocol is 9600 baud, 8-bit, 1 stop bit, no parity, and no flow control.

Commands and responses for programming the MVP 104GX from a host
system connected to the RS-232/RS-422 port are listed on the following
pages.

Host-to-MVP 104GX Communications

The MVP 104GX accepts SIS™ (Simple Instruction Set™) commands through
the RS-232/RS-422 port. SIS commands consist of one or more characters
per command field. They do not require any special characters to begin or
end the command character sequence. Each MVP 104GX response to an SIS
command ends with a carriage return and a line feed (CR/LF = ), which
signals the end of the response character string. A string is one or more
characters.

MVP 104GX-initiated messages

When a local event occurs, such as a front panel operation, the
MVP 104GX responds by sending a message to the host. The MVP 104GX-
initiated messages are listed below (underlined).

(c) Copyright 2000, Extron Electronics, MVP 104GX, Vx.xx

DB9 Pin Locations

Female

5

1

9

6

REMOTE

RS-232/RS-422

Advertising