12

The inner connecting power cord running from the switch box to the

motorized cartridge can be detached by unscrewing the compression nut

located at the motorized cartridge.

4-3-6

Removal of blockage from impeller / impeller replacement:

Once the bottom of the motorized cartridge is accessible, the fasteners retaining the volute can be removed and the

volute separated by pulling it away. The impeller chamber can now be cleaned if required, or the impeller can be replaced.

NOTE: the impeller has a left-handed thread. To remove, use a slotted screwdriver to hold the shaft and turn the impeller

clockwise.

4-3-7

Interconnect hose:

A hose connects the discharge of the motor cartridge (pump) to the discharge flange. To remove this hose, follow the

procedure to remove the discharge flange and motorized cartridge. Both ends of the hose are secured with clamps.

4-3-8

Control Switch:

The control switch cartridge is mounted to the main

cover with fasteners. The control has two power cords,

first is the main power cord that plugs into the house

receptacle and the other powers the motorized

cartridge. The motorized cartridge must be removed to

Impeller has a left handed thread