Liberty Pumps Ascent II User Manual

Page 17

Advertising
background image

©Copyright 2013 Liberty Pumps Inc. All rights reserved.

17

Air lock

The volute has a passage-way to allow trapped air to

escape. This passage-way must be cleaned of

obstruction

Application

The pumping capacity has been exceeded by the rate of

incoming water. Either reduce flow coming into the

macerator or reduce the pumping head.

Water backs up into shower tray

Alarm is not activated

General plumbing

Blockage or inadequate slope of pipe

Clear blockage in piping, or increase pitch of discharge

pipe. Typically ¼” drop per foot is adequate for a gravity

drain.

The inlet flappers of the Macerator are

not functioning

Clear any buildup in the Macerator holding tank that is

preventing the flappers from opening

Water backs up into shower tray

Alarm is activated

General plumbing or system is backing up

Damaged Impeller

Replace impeller

Volute inlet clogged

Clean volute’s inlet

Internal hose is damaged

Confirm the internal hose is functioning properly; if not it

must be replaced.

Air lock

The volute has a passage way to allow trapped air to

escape, this passage way must be cleaned of

obstruction

Incoming flow rate is greater than

pump capacity

The unit is capable of handling up to two shower heads

– multiple (3 and up) shower heads should be avoided.

Check valve failure of the Macerator

The discharge flange contains the check valve which

either requires cleaning or replacement

During the draining of the bathtub the alarm

sounds and / or water backs up into the toilet

General plumbing

The inflow is greater than the

macerator can handle

A ball valve should be installed between the tub and

macerator – throttle down or partially close the ball valve

until the macerator can handle the drainage rate from

the tub.

Macerator is noisy when running

General plumbing

Rattling piping

Both the discharge and vent plumbing should be

secured using the appropriate pipe clamp.

Foreign object in cutter basket

The access cover should be removed for manual

cleaning see section 4

Advertising