TROUBLESHOOTING CHART

RISK OF ELECTRIC SHOCK. ALWAYS DISCONNECT THE POWER SUPPLY BEFORE PERFORMING ANY SERVICE TO THE

MACERATING TANK.

PROBLEM

CAUSE

REMEDY

Toilet flushes normally but evacuates or drains

from the bowl slowly

macerator sounds normal and runs for 4

seconds, then after some time runs for 4

seconds.

NO alarm

Water is entering the macerator’s holding tank slowly.

The toilet or discharge extension might

be blocked.

The piping must be cleaned.

Poor vent

Unit must be vented properly to open air to allow water

to enter the macerator tank. Confirm vent is clear.

DO NOT USE A QUICK VENT

Accumulation in the strainer basket

Repetitively flush clean water and allow the macerator to

clear debris. If unit is unable to self-cure the blockage,

the access cover should be removed for manual

cleaning.

See Section 4.

Toilet flushes normally but does not evacuate or

drain from the bowl.

macerator sounds normal and runs for 4

seconds then remains off

NO alarm

Water is unable to enter the macerator’s holding tank

The toilet discharge or extension pipe

may be blocked.

The piping must be cleaned.

Unit is not vented correctly

Unit must be vented properly to open air to allow water

to enter the macerator tank. Confirm vent is clear.

DO NOT USE A QUICK VENT