2-9 NORMAL OPERATING CYCLE: The macerator’s IST switch is capable of distinguishing between different modes of operation and optimizes the

run time accordingly. Advanced run detection will energize the cutters once the unit detects a flush. In doing so, the cutters are spinning at

maximum speed (rpm) prior to fluid and debris reaching the cutting system. The unit may pulse during a shower or draining a bathtub because

the macerator can pump at a higher rate than the incoming flow.

2-10 ALARM: The macerator has an integral alarm that will sound if the unit cannot remove liquid or keep up with incoming water. If the alarm sounds,

a number of conditions could exist; please see the trouble shooting guide to determine the cause and solution. A silence button located on the

user interface touchpad will stop the audible alarm. The alarm light will continue to illuminate. Discontinue using the product until the problem

has been identified and resolved. In the event of a power outage, a 9-Volt battery will power the alarm. (Note: In the event of a power outage

and if necessary, the macerator will accept two flushes prior to alarm activation. After that, the unit should not be used again until the power is

restored.) The alarm automatically resets once a normal cycle is performed. If the yellow light is illuminated on the LED touchpad, the 9 volt

battery needs to be replaced. The expected life of the supplied battery is 5 to 7 years.

2-11 ACCESS COVER: The macerator has an access cover that can be removed to gain access to the pumping and macerating cartridge to remove

debris or perform maintenance. Once the right hand decorative cover and access cover have been removed, the cartridge can be slid towards

the opening to provide access to the basket and cutting mechanism. The blades or entire cutting base can be replaced if needed. See the

maintenance section 4-3 of this manual for detailed instructions.

NOTE: All installations should be done in accordance with federal, state and local codes. It is recommended that a certified or qualified

installer perform these operations. Do not use an air admittance valve or a mechanical spring-loaded venting device.

3-1

The bathroom layout should be designed prior to installation.

a) Make certain the power source (GFCI receptacle) is within range of the macerator’s 8’ power cord. The cord can be configured

to exit the unit on either the left or right side. Do not use an extension cord. When exiting the left side of the macerator the vent

flange must be removed so the cord can be routed between the positioning clips. Reinstall vent flange after routing the cord.

b) If possible, the right side of the macerator should remain unobstructed. An access cover is located under the decorative cover

that allows access to the cutting mechanism. In the event of a jam, the decorative cover as well as the access cover will need

to be removed from the macerator and working room to do so would be beneficial.

c) Auxiliary inlet ports are located on either side towards the back of the macerator’s tank. These ports can accept waste from

sink or tub/shower.

d) An optional discharge extension allows the macerator to be positioned behind a wall. For instance, the macerator could be

positioned on the floor of a linen closet or utility room. DO NOT fully frame unit into a wall -- access to macerator must be

maintained.

e) The macerator features Quickflip

tm

discharge and vent flanges that can be oriented in a vertical or horizontal orientation to best

fit your installation.

f)

A sink should be plumbed into one of the auxiliary inlets and not the discharge line of the macerator even if elevations would

allow such an installation. The discharge line is pressurized and the plumbing system needs to accommodate this.

g) The water supply line for the toilet tank is located on the left side. When roughing in, pay attention to allow for the macerator.
h) Long downward pitched runs of discharge piping, or piping where the point of discharge is at a lower elevation than the

macerator unit, should be designed to prevent siphoning from the macerator tank.

i)

Rough in dimensions – The toilet hold down fasteners should be located 16” from the wall and spaced 7” apart. This assumes

a typical baseboard of ¾” x 5.5” with ¾” quarter round. Actual baseboard dimensions must be taken into account during the

installation and thus rough in dimensions might change.