General information – Liberty Pumps Ascent II User Manual

Page 2

Advertising
background image

©Copyright 2013 Liberty Pumps Inc. All rights reserved.

2

Before installation, read the following instructions carefully. Each Liberty pump is individually factory tested to ensure

proper performance. Closely following these instructions will eliminate potential operating problems, assuring years of

trouble-free service.

Risk of electric shock. Always disconnect the macerator from the power source before handling or making

adjustments.

These pumps are not to be installed in locations classified as hazardous in accordance with the National Electric

Code, ANSI/NFPA 70.

Qualified personnel should only make the electrical connections and wiring for a pump installation.

This pump is supplied with a grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is

connected to a properly grounded, grounding-type receptacle.

This product must be connected to a ground fault circuit interrupter (GFCI) receptacle or circuit breaker.

Do not bypass grounding wires or remove ground prong from attachment plugs.

Do not use an extension cord.

The installation must be in accordance with the National Electric Code and all applicable local codes and ordinances.

The Macerator has a large opening to accept the discharge hub of a rear discharge toilet. DO NOT place hand or

other objects into this opening even if unit is unplugged. The macerator has razor sharp cutters within this opening.

Decorative covers must be installed for operation, a safety device is integrated into the covers to prevent unintended

operation. The unit may start when energized the first time.

Explosion hazard during installation. PVC cleaners, primers, and cements can release explosive vapors. These

heavier than air vapors can accumulate in the tank. The heat of soldering or sweating copper or other metal pipe can

ignite these vapors causing a violent explosion. If the unit is to be connected to copper discharge or vent piping, all

solvent welded PVC joints must be allowed to cure a minimum of 24 hours. The access cover must be removed to

allow the macerator to be thoroughly ventilated prior to sweating copper pipe near the unit.

Do not use macerator in water over 104

F.

Do not lift macerator by the power cord.

Do not use an air admittance valve or a mechanical spring-

loaded venting device.

1-1

INSPECTION UPON RECEIPT.

The Ascent II is shipped in 3 separate packages, the toilet tank

(model: Ascent II - TW), toilet bowl (model: Ascent II – RW or EW)

and macerating unit (model: Ascent II - MUW). The shipping

containers should be immediately inspected for damage that may

have occurred in shipment. Exercise care in opening the shipping

container to avoid damage to the contents. Remove any blocking

and packaging from within the containers.

Check all packaging for spare parts before discarding. Visually

check the macerating unit and any spare parts for damage.

Check for damaged electrical wires, especially where they exit the

macerating tank. Report any damage or shortage of parts to

Liberty Pumps 1-800 543-2550.

List of included parts:

Toilet Bowl

Toilet Tank

Macerator

Macerator tank

Rubber couplings with clamps

Reducing bushings

9-volt battery

Allen wrench - 3/16”

Grease packet

1. General Information