disconnect this cord. See instructions under the heading “Accessibility to Motorized cartridge 4-3-5” for details.

4-3-9

Toilet sealing ring:

The seal between the toilet and the macerator consists of a rubber ring connected to the macerator to which the toilet

slides into. The rubber ring stretches and forms a seal around the discharge hub of the toilet. This rubber ring is

replaceable by unclipping the plastic retainer and then pulling the ring outward. Installation is reverse, first slide the rubber

ring onto the macerator followed by the retaining ring.

5-1

BEFORE REFERRING TO TROUBLESHOOTING CHART

5-1-1 Check plumbing system. Flush toilet and ensure water supply is turned on.

5-1-2 Check electrical system. Ensure breaker and receptacle GFCI are on. Check condition of circuit breaker

or fuse. Ensure plug is not loose. If the pumping unit’s thermal overload has activated, it will take about 20

minutes to reactivate.

5-1-3 Ensure decorative covers are installed and fully seated such that safety switch is activated. The green

light should be solid green if safety switch is properly activated.

5-1-4 Check the hydraulic system. Check that the discharge pipe and vent pipe are not blocked.

5-1-5 If the macerating pump turns on intermittently without flushing the toilet or collecting water drainage from

sink, shower, or tub, check for leakage from the toilet tank flush valve.