Elmo Rietschle G-SAH User Manual

Page 8

Advertising
background image

/ PM7

SAH

25

45

55

75

95

155

215

235

275

355

505

dB(A)

50 Hz

74

82

82,5

85

84

77

83,5

89

88

85

89

60 Hz

74

82

82,5

85

84

77

84

89

89,5

86

92

dB(A)

50 Hz

-

-

-

89

-

-

-

99

96

95

100

60 Hz

-

-

-

89

-

-

-

99

97

97

102

kg

16,5

20

24,5

26,5

34

52

65

88

110

136

213,5

mm

337

348

390

390

417

449

552

620

647

734

777

mm

246

255

286

286

336

392

438

458

471

540

540

mm

269

298

324

324

410

447

489

545

567

620

620

8.08

Noise level (max.)

Sound power

Weight (max.)

Length (max.)

Width

Height

Trouble Shooting:
1.

Blower does not reach operating speed when starting:

1.1 Check that the incoming voltage and frequency corresponds with the motor data plate.
1.2 Check the connections on the motor terminal block.
2.

Motor starter cuts out blower:

2.1 Problem as per 1.1 and 1.2.
2.2 Incorrect setting on the motor starter.
2.3 Motor starter trips too fast.

Solution: Use a motor starter with a time delay trip (version as per IEC 947-4).

2.4 Blower is overloaded, i.e. pressure difference is too high.

Solution: Increase the inlet or outlet diameter of the application, on pipework increase the diameter of the pipework, avoid restrictions in the
line. Limit the pressure difference by limitation valves (optional extra).

2.5 Motor rating selected was too small.

Solution: If available use a blower with the next motor size (exchange of the motor only is not possible).

3.

Required pressure difference cannot be achieved:

3.1 Blower or motor rating selected, was too small.
3.2 Filters are contaminated.
3.3 Pressure loss into pipework too high.

Solution: Use bigger pipe diameter, avoid restrictions.

3.4 Leaks on the system.
4.

Blower operates at an abnormally high temperature:

4.1 Ambient or suction temperature is too hot.
4.2 Pressure difference is higher than permitted.
4.3 Cooling air flow is restricted.
5.

Exhaust noise (vacuum pump) or suction noise (compressor) are unacceptable:
Solution: Use an additional silencer ZGD (optional extra).

6.

Change over valve ZWS (accessory) does not work:

6.1 Check that the incoming voltage and frequency correspond with the information on the solenoid.
6.2 Change over valve is contaminated.

Solution: Dismantle and clean.

Appendix:
Repair on Site: For all repairs on site an electrician must disconnect the motor so that an accidental start of the unit cannot happen.
All engineers are recommended to consult the original manufacturer or one of the subsidiaries, agents or service agents. The address of the nearest
repair workshop can be obtained from the manufacturer on application.
After a repair or before re-installation follow the instructions as shown under the headings ”Installation and Initial Operation”.
Lifting and Transport: To lift and transport units SAH 95 to SAH 505 the eye bolt on the pump must be used.
The weight of the blowers are shown in the accompanying table.
Storage: SAH units must be stored in dry ambient conditions with normal humidity. We recommend for a relative humidity of over 80% that the pump
units should be stored in a closed container with the appropriate drying agents.
Disposal: The wearing parts (as listed in the spare parts lists) should be disposed of with due regard to health and safety regulations.
Spare parts lists:

E 556 / 1

SAH 25 —> SAH 155; SAH 215, 235, 275 (4 kW + 4,8 kW)

E 556 / 2

SAH 215, 235, 275 (5,5 kW –> 9 kW); SAH 355; SAH 505