Elmo Rietschle G-SAP User Manual

Page 8

Advertising
background image

/ PM7

SAP

50

90

110

150

180

220

300

380

450

530

710

1060

1500

dB(A)

50 Hz

75

81

81

87

86

88

87

86

90

93,5

92,5

99

99

60 Hz

77

81

82

87

87

89,5

91

86

90

92

94

99

100

dB(A)

50 Hz

-

-

-

91

94

98

95

92

99

100

99

108

108

60 Hz

-

-

-

92

94

99

100

92

99

100

101

108

108

kg

16

17

24,5

24,5

34

42

53

58

95

88

125

200

201

mm

328

340

362

369

411

429

464

490

608

634

664

764

790

mm

234

251

282

282

332

370

386

432

450

471

534

534

534

mm

267

297

322

322

381

414

443

486

525

561

617

639

606

Noise level (max.)

Sound power

Weight (max.)

Length (max.)

Width

Height

Trouble Shooting:
1.

Blower does not reach operating speed when starting:

1.1 Check that the incoming voltage and frequency corresponds with the motor data plate.
1.2 Check the connections on the motor terminal block.
2.

Motor starter cuts out blower:

2.1 Problem as per 1.1 and 1.2.
2.2 Incorrect setting on the motor starter.
2.3 Motor starter trips too fast.

Solution: Use a motor starter with a time delay trip (version as per IEC 947-4).

2.4 Blower is overloaded, i.e. pressure difference is too high.

Solution: Increase the inlet or outlet diameter of the application, on pipework increase the diameter of the pipework, avoid restrictions in the
line. Limit the pressure difference by limitation valves (optional extra).

2.5 Motor rating selected was too small.

Solution: If available use a blower with the next motor size (exchange of the motor only is not possible).

3.

Required pressure difference cannot be achieved:

3.1 Blower or motor rating selected, was too small.
3.2 Filters are contaminated.
3.3 Pressure loss into pipework too high.

Solution: Use bigger pipe diameter, avoid restrictions.

3.4 Leaks on the system.
4.

Blower operates at an abnormally high temperature:

4.1 Ambient or suction temperature is too hot.
4.2 Pressure difference is higher than permitted.
4.3 Cooling air flow is restricted.
5.

Exhaust noise (vacuum pump) or suction noise (compressor) are unacceptable:
Solution: Use an additional silencer ZGD (optional extra).

6.

Change solenoid valve or change over valve ZWS (accessory) does not work:

6.1 Check that the incoming voltage and frequency correspond with the information on the solenoid.
6.2 Change over valve is contaminated.

Solution: Dismantle and clean.

Appendix:
Repair on Site: For all repairs on site an electrician must disconnect the motor so that an accidental start of the unit cannot happen.
All engineers are recommended to consult the original manufacturer or one of the subsidiaries, agents or service agents. The address of the nearest
repair workshop can be obtained from the manufacturer on application.
After a repair or before re-installation follow the instructions as shown under the headings ”Installation and Initial Operation”.
Lifting and Transport: To lift and transport units SAP 180 to SAP 1500 the eye bolt on the pump must be used.
The weight of the blowers are shown in the accompanying table.
Storage: SAP units must be stored in dry ambient conditions with normal humidity. We recommend for a relative humidity of over 80% that the pump
units should be stored in a closed container with the appropriate drying agents.
Disposal: The wearing parts (as listed in the spare parts lists) should be disposed of with due regard to health and safety regulations.
Spare parts lists:

E 545 / 1

SAP 50 —> SAP 300; SAP 380, 450, 530 (4 kW + 4,8 kW)

E 545 / 2

SAP 380, 450, 530 (5,5 kW –> 9 kW); SAP 710; SAP 1060; SAP 1500

8.08