Franklin Fueling Systems T5 Series Fuel Management System Programming Guide User Manual
Page 39

35
Upload
When required, the backup configuration file will need to be reloaded onto the console to restore a previous setup. When
uploading, it is important to remember that network parameters may be affected by the change, rendering it unreachable
from a remote location. If the downloaded file contains an IP address different from the one currently in use, someone will
need to locally reprogram the correct address into the console in order to communicate remotely.
1. Open a web browsing application, type the IP address (the default IP Address is 192.168.168.168) into the address bar
of the browser window. The console will navigate to the Home Status page, indicated by the word Status in the header.
2. Left-click once on
Setup.
3. To upload a configuration file, click
Upload on the Setup page. At this point, the console may prompt for a password if
the proper access level has not been obtained.
4. An Upload Confirmation window will open. Left-Click
Browse to locate the correct file. Click on the file name, and then
click
Open.
This process may take a few moments for the console to apply the settings and reboot. To indicate that the update was
successful, you will see this notification window.