Page 17 of 19

Over Load Protection:

1.2 x Inom permanent overload capacity @30°C (86°F)

1.5 x Inom >10s

2 x Inom >5s

7.4 Mechanical

Dimensions:

43.8mm H x 440mm W x 360mm D

[1.73" H x 17.3" W x 14.2" D]

Weight:

7.4 kg (16.3 lb.) for 230Vac model

7.6 kg (16.8 lb.) for 120Vac model

7.5 Environmental

Operating Temperature:

-20 to +60°C (-4 to +140°F)

-20 to +50°C (-4 to +122°F) with full

performance

Storage Temperature:

-30 to +80°C (-22 to +176°F)

Operating Humidity:

0 to 95% relative, non-condensing

Heat Dissipation:

Forced air cooling

Operating Altitude:

1500m (4922 feet)

Audible Noise:

55dB ETS 300 753 Class 3.1

Standards

Safety Compliance:

Comply with EN 60950-1/UL 60950-1

Certification:

CE

RoHS:

Compliant

EMC:

EN300 386:2001 Class B compliance

MTBF:

200,000 hours as per Telcordia SR-332


The above information is valid at the time of publication. Consult factory for up-to-date ordering information. Specifications are subject to change without notice.