B&K Precision 9116 - Programming Manual User Manual
Page 21
![background image](/manuals/320504/21/background.png)
Query syntax: LIST:LINK:SEQuence?
Return parameter: 0~1023
LIST:SEQuence:REPeat <NR1>,<NR1>
This command is used to edit the running count of sequence which is linked to the List file.
Command syntax: LIST:SEQuence:REPeat<NR1>,<NR1>
Parameter: Parameter1 represents the sequence number,parameter2 corresponds to the
running count of the sequence (1~65535).
Query syntax: LIST:SEQuence:REPeat? <NR2>
Return parameter: 0~65535
LIST:SAVe
This command is used to save the list file in nonvolatile memory.
Command syntax: LIST:SAVe
Parameter: None
SEQUENCE Commands
SEQuence:EDIT
This command is used to select the list sequence to be edited.
Command syntax: SEQuence:EDIT <NR1>
Parameter: 1~10
Query syntax: SEQuence:EDIT?
Return parameter: 1~10
SEQuence:STEP:ACTive
This command is used to select the steps to be activated of sequence.
Command syntax: SEQuence:STEP:ACTive <NR2>
Parameter: 0~1023
Query syntax: SEQuence:STEP:ACTive?
Return parameter: 0~1023
SEQuence:VOLTage
This command is used to edit the voltage of specified step of the sequence.
Command syntax: SEQuence:VOLTage <NR1>,<NRf>
Unit: V
parameter: Parameter1 represents the number of step to be edited. Parameter2 is the voltage
(MIN~MAX).
Query syntax: SEQuence:VOLTage? <NR1>
Return parameter: MIN~MAX
SEQuence:CURRent
This command is used to edit the current of specified step of a sequence file.
Command syntax: SEQuence:CURRent<NR1>,<NRf>