Standard commands – B&K Precision 9171-9174 - Manual User Manual

Page 136

Advertising
background image

124


TIMER:MINute

Description:

Configures/Queries the output timer hours.

Syntax:

TIMER:MINute<SP><hour>

TIMER:MINute?

<hour> - 0 - 59

Example:

TIMER:MIN 40

Sets the output timer to 40 minutes.

Query:

TIMER:MIN?

Return String:

40

Format:

<NR1>


TIMER:SECond

Description:

Configures/Queries the output timer seconds.

Syntax:

TIMER:SECond<SP><hour>

TIMER:SECond?

<hour> - 0 – 59

Example:

TIMER:SEC 20

Sets the output timer to 20 seconds.

Query:

TIMER:SEC?

Return String:

20

Format:

<NR1>


Standard Commands

The following commands are instrument specific and apply to all
models, with the exception of some that apply to dual channel
models only (see the notes under some of the commands for details).
Most of these commands function the same way as most of the
SCPI commands described in the previous section. For example,
MEASure:CURRent? functions the same as IOUT?.