128

OCP/OCP2

Note:

OCP2 command is for dual channel models only.

Description:

Configures/Queries the over current protection state.

For dual channel models, use OCP2 command for

channel 2.

Syntax:

OCP<SP><state>

OCP2<SP><state>

OCP?

OCP2?

<state> - ON or 1 to turn ON

- OFF or 0 to turn OFF

Example:

OCP2 ON

Enables OCP for channel 2 on a dual channel model.

Query:

OCP?

OCP2?

Return String:

OFF

Format:

<state>


OISET/OISET2

Note:

OISET2 command is for dual channel models only.

Description:

Configures/Queries the over current protection value.

For dual channel models, use OISET2 command for

channel 2.

Syntax:

OISET<SP><current>

OISET2<SP><current>

OISET?

OISET2?

<current> - 0 – max. rated current

Example:

OISET 9.124

Sets OCP protection to 9.124 A .

Query:

OISET?

OISET2?

Return String:

9.124

OCP is set to 9.124 A.

Format:

<NRf>