B&K Precision 9171-9174 - Manual User Manual

Page 142

Advertising
background image

130

OVP/OVP2

Note:

OVP2 command is for dual channel models only.

Description:

Configures/Queries the over voltage protection state.

For dual channel models, use OVP2 command for

channel 2.

Syntax:

OVP<SP><state>

OVP2<SP><state>

OVP?

OVP2?

<state> - ON or 1 to turn ON

- OFF or 0 to turn OFF

Example:

OVP2 ON

Enables OVP for channel 2 on a dual channel model.

Query:

OVP?

OVP2?

Return String:

Format:

ON

<state>


OVSET/OVSET2

Note:

OVSET2 command is for dual channel models only.

Description:

Configures/Queries the over voltage protection value.

For dual channel models, use OVSET2 command for

channel 2.

Syntax:

OVSET<SP><voltage>

OVSET2<SP><voltage>

OVSET?

OVSET2?

<voltage> - 0 – max. rated voltage

Example:

OVSET 70.000

Sets OVP protection to 70.000 V

Query:

OVSET?

OVSET2?

Return String:

70.000

OVP is set to 70.000 V

Format:

<NRf>





Advertising
This manual is related to the following products: