B&K Precision MDL Series - Programming Manual User Manual

Page 54

Advertising
background image

54

[SOURce:]CURRent:SLEW:NEGative

Channel Specific
This command sets the slew rate of the current for negative transitions. MAXimum sets the slew to the

fastest possible rate. MINimum sets the slew to the slowest rate.

Command Syntax [SOURce:]CURRent:SLEW:NEGative <NRf+>

Parameters see specifications

Unit A (amps per micro second)

Examples CURR:SLEW:NEG 0.0001

Query Syntax [SOURce:]CURRent:SLEW:NEGative?

Returned Parameters <NR3>

Related Commands CURR:SLEW


[SOURce:]CURRent:PROTection:STATe

Channel Specific
This command enables or disables the overcurrent protection feature.

Command Syntax [SOURce:]CURRent:PROTection:STATe <Bool>

Parameters 0 | 1 | OFF | ON

*RST Value OFF

Examples CURR:PROT:STAT 1

Query Syntax [SOURce:]CURRent:PROTection:STATe?

Returned Parameters <NR3>

Related Commands CURR:PROT

[SOURce:]CURRent:PROTection

Channel Specific
This command sets the soft current protection level. If the input current exceeds the soft current

protection level for the time specified by CURR:PROT:DEL, the input is turned off.

NOTE: Use CURR:PROT:DEL to prevent momentary current limit conditions caused by programmed

changes from tripping the overcurrent protection.

Command Syntax [SOURce:]CURRent:PROTection:LEVel <NRf+>

Parameters 0 through max. Rated current

Unit A (amps)

Advertising