B&K Precision MDL Series - Programming Manual User Manual
Page 56

56
Channel Specific
These commands specify the transient level of the input current. The transient function switches
between level A and level B.
Command Syntax [SOURce:]CURRent:TRANsient:ALEVel <NRf+>
[SOURce:]CURRent:TRANsient:BLEVel <NRf+>
Parameters 0 through max. Rated current
Unit A (amps)
Examples CURR:TRAN:ALEV 5 CURR:TRAN:BLEV 0.5
Query Syntax [SOURce:]CURRent:TRANsient:ALEVel?
[SOURce:]CURRent:TRANsient:BLEVel
Returned Parameters <NR3>
Related Commands CURR:
[SOURce:]CURRent:TRANsient:AWIDth
[SOURce:]CURRent:TRANsient:BWIDth
Channel Specific
These commands specify the transient pulse width of the input current.
Command Syntax [SOURce:]CURRent:TRANsient:AWIDth <NRf+>
[SOURce:]CURRent:TRANsient:BWIDth <NRf+>
Parameters 1 to 65535 us
Unit S (seconds)
*RST Value 500uS
Examples CURR:TRAN:AWID 0.001 CURR:TRAN:BLEV 0.02
Query Syntax [SOURce:]CURRent:TRANsient:AWIDth?
[SOURce:]CURRent:TRANsient:BWIDth
Returned Parameters <NR3>
Related Commands CURR:
[SOURce:]CURRent:HIGH
[SOURce:]CURRent:LOW
Channel Specific
These commands set the high and low voltage level when the load is in constant current mode.
Command Syntax [SOURce:]CURRent:HIGH <NRf+>
[SOURce:]CURRent:LOW <NRf+>
Parameters see specifications for voltage range
Unit V (volts)
Examples CURR:HIGH 5