Restore power and verify operation.

Figure 2.

Conduit through Mount (Figure 3) Installation Steps:

For maximum long term reliability and light output, the light must be installed in free air.

o

The Linear fixture design incorporates an over-temperature control circuit that
reduces input power should internal temperatures reach a maximum level. In this
event, light output may be reduced.

The Linear fixture is threaded for 3/4” NPT, at the center and each end of the Power
Supply Housing, in order to be assembled to conduit.

o

Attach conduit and sealing fittings within .75” of the Housing as shown in figure 3.
Use conductive pipe sealant for all fittings and conduit.

o

Remove the Power Supply Cover to attach incoming power to the fixture.

o

Prior to replacing the Cover ensure that the o-ring seal is properly seated in the o-
ring groove. Reattach the Cover using the screws and lock washers previously
removed. Tighten all screws to 15 in/lbs.

o

Tighten 1/4-20 anti-rotational screw in order to secure the fixture to the conduit.

Connect power cable conductors as follows:

o

Green to Safety Ground using green screw supplied in housing.

o

Neutral to White

o

Line to Black

Restore power and verify operation.