Section 2: Wiring and Mounting

Warning:
Remove power from all wiring and circuitry before installing or working on the
Beacon.

Wiring the Beacon
The Beacon only requires a connection to 120 / 240 VAC, 50/60 Hz power. The
ground wire must be connected for proper operation and protection of the
Beacon.

Mounting the Beacon
Dialight recommends the installation of one or more lightning rods near the
installed Beacon. The lightning rods should extend a minimum of three feet
above the height of the Beacon.

The Beacon is mounted to the tower pedestal utilizing customer supplied ½”
hardware. Six mounting holes are provided on the Beacon base (Figure 2).
These mounting holes will align with most tower pedestals. The Beacon must be
installed level according to the bulls-eye level inside the light engine to maintain
light output in accordance with FAA requirements.