Dialight D464R13001 Vigilant L864 LED Based Red/Infrared Medium Intensity Beacon User Manual

Page 6

Advertising
background image

Document No.

9100-127-1541-99 Rev A

November 17, 2011

_____________________________________________________________________

_____________________________________________________________________________

Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727

Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com

6 of 12


4.1 Lightning Protection

The Beacon incorporates protection against voltage surges (as induced by
nearby lightning strikes for example) by means of a Metal Oxide Varistor (MOV)
and Gas Discharge Tube (GDT) arrangement.



Section 5: Maintenance and Troubleshooting

No regularly scheduled maintenance is required for the Beacon.

General cleaning of the Dome Assembly should be done using soapy water. No
other cleaning solutions are recommended. Abrasive compounds will scratch the
Dome Assembly.

Table 1 Lists possible faults and repair procedures for the L-864 Red Beacon

Table 1 Troubleshooting

Symptom

Possible Cause

Corrective Action

Beacon does not light

No AC power


LED Failure



Power supply Failure

Verify proper AC levels from
power source thru supply
lines.

Replace LED Module



Replace power supply

Beacon does not flash Refer to controller

documentation
supplied by the
manufacturer.


Repair and Replacement

Refer to Table 1 for troubleshooting procedures.