Analogue input sampling, Output characteristics, Motec appendices 49 analogue input sampling – MoTeC C185 User Manual

Page 54

Advertising
background image

MoTeC

Appendices

49

Analogue Input Sampling

4 times oversampling is scheduled with samples taken every 250 usec,
providing measurements every 1 msec.
The following inputs are sampled at 250 usec, with microsecond offsets as
shown in the table:

Offsets

0.0 usec

+1.5 usec

+3.1 usec

0.0 usec

AT1

AV1

AV15

+9.3 usec

AT2

AV2

AV16

+20.9 usec

AT3

AV3

AV17

+30.1 usec

AT4

AV4

AV18

+39.4 usec

AT5

AV5

AV19

+51.0 usec

AT6

AV6

AV20

+60.3 usec

AT7

AV7

AV21

+71.9 usec

AT8

AV8

AV22

+81.1 usec

N/A

AV9

AV23

+90.4 usec

8VSEN

AV10

AV24

+102.0 usec

5VSEN

AV11

INT TEMP

+111.3 usec

ACCELX

AV12

SPD1

+122.9 usec

ACCELY

AV13

SPD2

+132.1 usec

ACCELZ

AV14

SPD3

+141.4 usec

N/A

BAT VOLTS

SPD4

Output Characteristics

Output Type:

Open Collector (Drives to ground) with weak pull-up
(10 k

Ω) to battery positive

Current:

1.0 A max, current limited & thermal overload protected

Output Clamp:

40 V Flyback Clamp (no clamp diode to supply).

Advertising