CAN Bus Wiring Requirements

• The CAN bus should consist of a twisted pair trunk with 100R (0.25 watt)

terminating resistors at each end.

o

If the CAN bus is less than 2 meter (7 ft) long, a single termination

resistor may be used.

• The preferred cable for the trunk is 100R data cable.
• The maximum length of the bus is 16 meter (50 ft)
• CAN devices (such as MoTeC Dash Loggers, ECUs etc) may be

connected to the trunk with up to 500 mm (20 in) of twisted wire.

CAN-LO

CAN-HI

10

0

R

10
0

R

CA

N-

L

O

CA

N-

H

I

CAN

Device

500 mm
max

<< CAN Bus >>

500 mm max

100R Terminating
Resistors at each
end of the CAN Bus

CA

N-

L

O

CA

N

-HI

CAN

Device

CA

N-

L

O

CA

N-

H

I

CAN

Device

These wires must be twisted

Minimum one twist per 50 mm (2 in)