4 electrical connection 4.4.1 safety rules, 2 connection, 5 pneumatic connection – CEMB USA ER85 Installation Manual User Manual

Page 10: English

Advertising
background image

ENGLISH

Installation manual Rev. 03-2012

10

CAUTION:

U

SING

NON

-

ORIGINAL

ACCESSORIES

MIGHT

COMPROMISE

THE

MEASURING

QUALITY

. C

ONTACT

THE

MANUFACTURER

FOR

THE

SUPPLY

OF

SPECIAL

ADAPTERS

OR

SPARE

PARTS

OF

ANY

KIND

.

4.4 ELECTRICAL

CONNECTION

4.4.1 Safety rules

Before performing any operation, read and apply the following:

Make sure that the main electric cabinet to which the machine is connected is connected to the earth circuit and

is adequately protected as required by the regulations in force in the country where the machine is installed.
The socket to which the machine is connected must have a slow acting safety switch calibrated to 4 A (230V) or
8A (115V).
Check that the mains voltage and frequency correspond to the values indicated on the machine identifi cation

plate.
The socket to which the machine is connected must be dimensioned to support the power absorbed up to a maxi

mum of 1.1 kW.

4.4.2 Connection

The machine is supplied with a single-phase cable to which a plug conform to the regulations must be connected. If
an extension needs to be used, bear in mind that the wire cross-section may not be less than 2.5 mm

2

. Make sure

that the extension is arranged so that it does not constitute a risk or obstruction.

WARNING

T

HE

CONNECTION

TO

THE

SINGLE

-

PHASE

MAINS

MUST

ALWAYS

BE

MADE

BETWEEN

PHASE

AND

NEUTRAL

AND

NEVER

BETWEEN

PHASE

AND

EARTH

!

IT IS

STRICTLY

PROHIBITED

TO

TURN

ON

THE

MACHINE

IF

IT

IS

NOT

PROPERLY

CONNECTED

TO

EARTH

ACCORDING

TO

THE

TECHNICAL

SPECIFICATIONS

SET

OUT

IN

THE

REGULATIONS

IN

FORCE

. I

N

ANY

EVENT

,

THE

ELECTRICAL

CONNECTIONS

MUST

BE

CARRIED

OUT

EXCLUSIVELY

BY

A

SPECIALISED

TECHNICIAN

.

4.5 PNEUMATIC CONNECTION

If the machine is equipped with a pneumatic locking/release spindle and/or zero weight lift, it needs to be fed with
compressed air at 8-10 bar. The compressed air coupling is positioned on the rear of the machine. The compressed
air must be clean and dry. The pipes and pipe fittings must be properly connected by appropriately trained personnel.
The warranty does not cover damage caused by the absence of an adequate air filtration system.